  • Reasons and solutions for water leakage of cooling tower chassis

    Reasons and solutions for water leakage of cooling tower chassis03-05

    Causes and solutions for water leakage in the cooling tower chassis? The cooling tower chassis is the place where the water is filled. Because of the water for many years, the chassis leaks in many cases. Today I will tell you the main reasons for the leakage of the cooling tower chassis:

  • Daily maintenance and maintenance of closed cooling towers

    Daily maintenance and maintenance of closed cooling towers03-03

    The closed cooling tower is a shell-and-tube heat exchanger placed in the tower, with the help of the heat exchange of circulating gas, spray water and circulating water to ensure the cooling effect. The following is a brief introduction to the maintenance of the closed cooling tower of the Kangming closed cooling tower for you.

  • Application range of closed cooling tower

    Application range of closed cooling tower02-26

    Due to the use of T2 copper tubes and stainless steel heat exchangers, the closed cooling tower adopts aluminum alloy cooling fans and evaporative condensers for dual heat dissipation, and closed cooling liquid circulation. It is widely used in petroleum, chemical, foundry, thermoelectric and other industries. .

  • Reasons and solutions for the increase in water temperature of cooling tower in summer

    Reasons and solutions for the increase in water temperature of cooling tower in summer02-25

    There is a big difference between using a cooling tower in winter and using it in summer. In summer, the environment temperature is high, so the heat exchange will be affected, and the temperature of the spray still cannot drop. The cooling tower temperature is high in summer, and the solution is difficult to cool down.

  • What are the precautions for cooling tower shutdown in winter

    What are the precautions for cooling tower shutdown in winter02-24

    Precautions for cooling towers during operation and rest in winter: 1) Drain circulating water and spreading water. 2) In the case of a closed type, please open the circulating water drain, exhaust port, and drain valve of the diffuser water pump.

  • Cooling tower maintenance and site setting method

    Cooling tower maintenance and site setting method02-24

    Some introductions of cooling tower manufacturers for cooling tower maintenance, setting up the site, and cooling heat-resistant temperature

  • Calculation method of water supply for air conditioning cooling tower

    Calculation method of water supply for air conditioning cooling tower02-23

    What is the calculation method for the water supply of the air conditioning cooling tower? Water loss by evaporation (E) E = Q/600 = (T1-T2)×L/600; E represents the amount of evaporated water (kg/h); Q represents the heat load (Kcal/h); 600 represents the latent heat of evaporation of water (Kcal /h); T1 represents the water temperature (℃)

  • Environmental protection, energy saving and maintenance methods for closed cooling towers?

    Environmental protection, energy saving and maintenance methods for closed cooling towers?02-23

    How many water pumps does a closed cooling tower need? There is no immediate response to this question, because in the case of the overall design of the fluid cooling tower, in the refrigeration plan presented by the customer, it is generally carried out with water pumps based on specific conditions.

  • Analysis of daily causes of water leakage in cooling tower

    Analysis of daily causes of water leakage in cooling tower02-22

    With the popularization of production and use of cooling towers, the editor of trlon air conditioners below will give you an analysis of the specific reasons for the daily leakage of closed cooling towers. For details, please see the analysis in this article.

  • What are the hazards caused by the unclean drainage of closed cooling towers?

    What are the hazards caused by the unclean drainage of closed cooling towers?02-05

    Everyone should not be unfamiliar with closed cooling towers. Then everyone knows what impacts the daily closed cooling towers will cause when the drainage is not clean. Below trlon air conditioners will take you to analyze the serious consequences and the serious consequences of unclean drainage of closed cooling towers. Performance characteristics

 268   Home Pripage 14 15 16 17 18 19 20 21 22 23 Nextpage LASTPAGE

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba