Comparison of cooling tower and external turbine

Author:Trlon  Views:  Time:2020-11-27
Comparison of cooling tower and external turbine

  External turbine: Installed at the position of the motor outside the wind tube, and is driven by a soft connection to the gearbox to drive the fan to rotate.4cdCooling tower noise reduction treatment manufacturer

  Comparison of 5 aspects of similar cooling tower products:4cdCooling tower noise reduction treatment manufacturer

  1) The external water turbine is installed on the motor position outside the cooling tower air cylinder, and the water inlet and outlet pipe connections of the water turbine are all connected outside the air cylinder.4cdCooling tower noise reduction treatment manufacturer

  2) The external water turbine is installed outside the cooling tower fan. As long as the inlet and outlet valves of the turbine are closed and the bypass valve is opened, the system can start normal spraying (without affecting the production process), and can be maintained and repaired at any time. There is no need for hoisting to enter the site, saving time and money.4cdCooling tower noise reduction treatment manufacturer

  3) The external water turbine is installed at the click position outside the cooling tower fan, and the drive shaft is connected to the designed special gearbox.4cdCooling tower noise reduction treatment manufacturer

  4) The working condition of the external turbine is outside the wind tunnel, away from the high-heat and humid environment, and various sensing devices can accurately transmit information.4cdCooling tower noise reduction treatment manufacturer

  5) When the flow is much lower than the design value, the external turbine can also be combined and split to work, so that part of the flow of the cooling tower next to it can be used to meet the turbine's work, and then distributed to the cooling tower next to the average spray . Merging and re-dividing not only solves the energy-saving transformation effect of low-flow cooling towers, but also effectively reduces the start-up time of the side tower motors of low-flow cooling towers (usually only for 7, 8, and 9 months), thereby realizing the improvement of an external type The water turbine can save electricity for one and a half motors.4cdCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/news/245.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba