Trlon air conditioner manufacturers have silent cooling towers, closed cooling towers and cooling tower noise reduction, maintenance and transformation services.
National Service Hotline National Service Hotline:

4008-8383-95

Your current location:HOME > News > Industry News

Industry News

Cooling tower manufacturers tell you how to choose energy-saving and environmentally friendly cooling towers

Author:Trlon  Views:  Time:2020-10-10
Cooling tower manufacturers tell you how to choose energy-saving and environmentally friendly cooling towers
Everyone also understands that in the current market decision, consumers pay special attention to the price of many people in the stage of their decision, whether in the choice of cooling towers or other product models. Therefore, it can be seen that the price of a cooling tower is actually a key factor for consumers to decide. Next, I will give you a specific introduction to its factors:cvSCooling tower noise reduction treatment manufacturer
The price is high. If in the cooling tower selection, the cooling tower has a particularly high price, so few consumers are determined. In the final analysis, the cooling tower with too high price can not be spent by ordinary consumers, and the cooling tower itself has a market Where is the value, so the sales volume of cooling towers that are too expensive in the market is not very good.cvSCooling tower noise reduction treatment manufacturer
The price is relatively low. What’s different from the above is that if the price of the cooling tower is relatively low in the choice of cooling tower, then there are not many consumers in the market to make the decision. After all, the current market Many consumers have rich experience in buying and selling, and its application function must not be guaranteed if the price is too low.cvSCooling tower noise reduction treatment manufacturer
Therefore, it can be seen that in the choice of cooling tower, the price of the cooling tower has a very large factor in the decision of consumers. If the cooling tower is to have a good development trend in the market, it must be in its development trend. Set a reasonable price.

1. Socio-economic benefits

①Under the premise of ensuring the technical parameters of the design scheme, the water-driven fan is used to replace the fan motor, which basically saves the energy consumption of the motor, and saves energy and electricity by 100%;cvSCooling tower noise reduction treatment manufacturer
②The floating water loss of the water-driven fan cooling tower is only one-tenth of the traditional cooling tower, which can reduce the supplementary water consumption and save the relative water expenses. At the same time, it can reduce the factors of floating water on the surrounding environment;cvSCooling tower noise reduction treatment manufacturer
③Because the water driven fan cooling tower removes the fan motor and reducer, it can greatly reduce the vibration and noise of the cooling tower and reduce the environmental pollution;cvSCooling tower noise reduction treatment manufacturer
④Because the fan motor and reducer are removed from the water driven fan cooling tower, the relative maintenance cost can be saved. The water turbine is a kind of product with high reliability. Since the renovation and transformation of the cooling tower water-driven fan was put on the market five years ago, there has been no maintenance record so far.

2. Advantages of renovation

Energy saving and electricity saving: 100% energy saving and electricity saving.cvSCooling tower noise reduction treatment manufacturer
Safety factor:cvSCooling tower noise reduction treatment manufacturer
①Traditional cooling tower motors have potential dangers of electric leakage, injury, and spark explosion. However, the updated cooling tower does not require electricity, which can prevent the safety risks caused by electric leakage, power failure, and spark explosion from the source. The safety factor can be operated within the explosion-proof range;cvSCooling tower noise reduction treatment manufacturer
② The motor and reducer are eliminated in the water-driven fan cooling tower, which moves the center of gravity of the cooling tower down, and improves the safety factor of the operating environment.cvSCooling tower noise reduction treatment manufacturer
Good cooling efficiency: As the season changes, the speed of the water-driven fan increases and decreases with the increase or decrease of the circulating water volume, and the air volume also increases and decreases, so that the water-to-air ratio of the cooling tower is stable at the best state, and the cooling effect is realized the best.cvSCooling tower noise reduction treatment manufacturer
Energy saving and environmental protection:cvSCooling tower noise reduction treatment manufacturer
①Because the water driven fan cooling tower saves the fan motor and reducer, it can reasonably reduce the vibration and noise caused by gear transmission and sliding friction, curb the possibility of oil leakage, and greatly reduce environmental pollution;cvSCooling tower noise reduction treatment manufacturer
②The water drift rate of the water-driven fan cooling tower is only 5/100,000, which can reasonably reduce the factors of water drift on the surrounding environment.cvSCooling tower noise reduction treatment manufacturer
Safe and reliable:cvSCooling tower noise reduction treatment manufacturer
This product has rigorous design, reasonable configuration, stable operation, high stability, and can operate continuously for a long time without wearing parts. The service life can reach 80,000 hours.cvSCooling tower noise reduction treatment manufacturer
high efficiency:cvSCooling tower noise reduction treatment manufacturer
The turbine shaft is directly connected with the fan, and there is no need for other reducers, transmission shafts, etc. to be connected in the middle.cvSCooling tower noise reduction treatment manufacturer
Few points of equipment failure:cvSCooling tower noise reduction treatment manufacturer
The encapsulation of the rotating part is formed by one-time compression molding, which completely isolates the rotating part from the water in the water chamber of the turbine. Under the guarantee of the above technical conditions, the turbine can achieve maintenance-free long-term operation, so that the cooling tower can Long time trouble-free operation, as a result, not only greatly saves customers a huge amount of water and electricity expenses, but also greatly saves the cost and manpower of maintenance and replacement of cooling tower motors and reducers. In addition, replacing the motor, reducer and transmission part with a hydraulic fan naturally reduces system failure points. At the same time, the motor, reducer, etc. are prone to short circuit burns, high temperature corrosion, leakage, and slippage in an environment with high temperature and humidity. For water-driven fans, most of the system fault sources of these system faults are no longer available.cvSCooling tower noise reduction treatment manufacturer
Convenient after-sales maintenance: If there is a system failure, the maintenance of the water-driven fan cooling tower is also very simple. You only need to replace some standard parts, which saves a lot of cumbersome after-sales maintenance of motors and reducers.

Article Address:https://www.trlen.com/news/154.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba