In the actual operation of a closed cooling tower, the loss of circulating water is inevitable. The majority of the loss should be estimated based on the equipment of the closed cooling tower. What are the key aspects of the loss of circulating water in the closed cooling tower Caused by:
Closed cooling towers have become an indispensable cooling device for the water circulation system, but some customers who are already using closed cooling towers will tell us why they are in the process of using closed cooling towers. Although the amount of floating water in a closed cooling tower should be very small under normal conditions, some reasons can also cause a very obvious floating water situation in the closed cooling tower, which will be very headache at this time, because these conditions, The following closed cooling tower manufacturer China trlon energy-saving air conditioner summarized a few points for you why the phase closed cooling tower is floating, and I look forward to helping you.
1. Definite volatilization loss: Because the water circulation system of the glass fiber reinforced plastic closed cooling tower is open, the circulating water will immediately touch the gas, and it is inevitable that it will be volatilized, but the amount of volatilization is relatively small, which probably accounts for the total circulating water flow. Between 0.2-0.3% of the two.
2. Drift loss: Because the key to the operation of a closed cooling tower depends on the rotation of the tower fan, which causes a cyclone and discharges the cold and wet gas to the outside of the tower; the greater the exhaust air volume of the closed cooling tower, the greater its adsorption force. The humid air contains a lot of moisture, which is usually discharged out of the tower by the adsorption force of the fan. This is why there is fog or floating water on the air cylinder of the closed cooling tower; under normal conditions, the closed cooling tower The floating water must be between 1-3%, but if the closed cooling tower is not equipped with a water collector or a water baffle, the floating rate of the closed cooling tower can exceed about 10-20%. This is why some closed cooling towers are drizzled within 50 meters of the surrounding area. The most important factor is that the closed cooling towers do not have water collection equipment.
3. Wind blowing loss: water will float out of the air inlet window of the closed cooling tower when the wind is strong. The key factor is the wind blowing. If this kind of situation occurs, you can also add a little water baffle or guide moderately. Flow board.
4. Wastewater treatment and dredging loss: Because the water tray of the closed cooling tower is in the open environment, it is inevitable that there will be sand, silt, algae, etc., and the closed cooling tower will also cause the loss of circulating water in the sewage treatment process. .
In winter, the loss of circulating water in closed cooling towers is relatively small. Usually in summer, the water in closed cooling towers is relatively large whether it is sure to float or volatilize. Therefore, it is recommended to expand the water supply of closed cooling towers in hot summers. The flow rate can not only deal with the water loss of the closed cooling tower, but also reduce the water temperature. The above is the introduction of the circulating water loss in the phase closed cooling tower. Learn more about the closed cooling tower (http:/ /www.trlonct.com), the content of closed cooling towers, we sincerely invite you to go to trlon in China to learn.