What is the general water flow loss due to volatilization of FRP cooling towers? This is a professional phenomenon. This article will introduce in detail the simple and convenient calculation method of the volatile water flow rate. Although it has an error with the actual evaporation, it has a key use value as a reference data information.
Volatilization is the key way to refrigerate the working fluid. The volatilization loss generally means the working efficiency of the glass fiber reinforced plastic cooling tower and the heat generation of the machinery and equipment. There is a calculation method for calculating the volatilization loss rate:
Volatilization loss (m3/hr)=0.0008x1.8x cycle rate (m3/hr)x(T1-T2)
T1: Entering water temperature
T2: Water outlet temperature
Volatilization is produced anytime and anywhere. It is the process of water changing from liquid to gas or vapor. The working principle of the refrigeration of FRP cooling tower is that the working fluid is volatilized when it touches the air. Even so, you can also be familiar with the volatilization in the open-loop FRP cooling tower anytime and anywhere. There is also a fan in the glass fiber reinforced plastic cooling tower to assist in volatilization and shorten the cooling time. (Contact the manufacturer to familiarize yourself with the working principle of FRP cooling towers.)
FRP cooling tower uses a water circuit to take away the heat. In this process, part of the cooling water will be volatilized, which is called volatilization loss. The volatilization loss generally means the working efficiency of the glass fiber reinforced plastic cooling tower and the heat generation of the machinery and equipment. However, scale will also be produced during the volatilization process. This kind of situation will reduce the heat transfer efficiency of the FRP cooling tower. By the way, it will also enhance the lotion. (Familiar with the relationship between scale and operation efficiency of FRP cooling tower.)
At this time, you are likely to have a question "Volatilization loss generally means the working efficiency of FRP cooling towers and the heat generation of machinery and equipment. However, how can we reduce the loss rate of vaporization?" The general solution is to reduce the airflow. Volume, it also helps reduce the functional loss of FRP cooling towers. Reduce the air volume by reducing the fan speed and applying a variable frequency motor. You can also consider using a closed-circuit glass fiber reinforced plastic cooling tower, because it can also reduce the need for makeup water and reduce the scale deposited in the heat exchange process.
5, contact trlon cooling tower manufacturer
Trlon cooling tower manufacturer Teling Air Conditioning has a history of several years. We are committed to dealing with the phenomena related to scale deposition, industrial equipment refrigeration and machine maintenance. If there is a cooling tower phenomenon, you can contact us anytime and anywhere.
Article Address:https://www.trlen.com/baike/463.html
Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.
Contact:Mr. Wang
Free Hotline:4008-8383-95
Company Email:sales@trlon.com
Web Site:https://www.trlen.com/
Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen