The following is the method to judge the aging degree of the packing in the closed cooling tower. Closed cooling tower can also end the recovery and use of waste heat. How does it end? Let's share it with us.
Take the boiler to heat the water for example, the water will be heated to form a relatively high pressure steam temperature, and then to propel the steam turbine to generate electricity. Then it is discharged into the condenser through the exhaust gas, and turns the exhaust gas into water by virtue of the function of the closed cooling tower, which is recycled back to the boiler for use.
In this process, waste heat is transferred to the cooling water in the closed cooling tower, raising the temperature of the water. At the same time, it can also transmit a lot of the heat generated above to the air, so if the equipment is equipped with other equipment, it may also have a greater effect.
Closed cooling tower is through the heat conduction of circulating cooling water and cold and dry air, and combined with the transpiration of circulating cooling water, in order to take away the latent heat of gasification and then reach the purpose of lowering water temperature. That is to say, when the closed cooling tower is running, it needs to have a certain pressure cycle.
In this state, after the cooling water enters the closed cooling tower through the inlet pipe, it will be atomized by the swirling jet of the atomizer of the manufacturer of the closed cooling tower. After all, it forms mist vapor and jets toward the top of the tower. At the same time, the backthrust generated by the cooling tower jet will drive the active rotating device to rotate, and then spray the entire water throughout the tower.
How to distinguish the aging degree of the packing inside the closed cooling tower?
After the aging of the packing of the closed cooling tower, it will become fragile. Under the impact of the spray water of the cooling tower, it will become debris into the pool at the bottom. In this way, not only the cooling efficiency of the cooling tower is affected, but also the equipment circulation treatment can not be completed. Replacing the filler is the only solution, but before that you need to test the aging of the filler.
Assuming that the filler is normal aging fall, all the filler used should be replaced, assuming that it is because of the fall formed by external forces, then you only need to replace the damaged filler. When the packing is replaced in batch, it is necessary to ensure that the area of the packing is not less than the area at that time. In the case of replacing the single packing, it should be ensured that the size and thickness of the material are consistent with the original.