Precautions for balance pipe of FRP cooling tower

Author:Trlon  Views:  Time:2021-05-06
Precautions for balance pipe of FRP cooling tower

  Today is Thursday, and all of us are going to read the article on cooling tower balancing tubes today.What are the installation matters of FRP cooling tower and balance pipe of cooling tower4KeCooling tower noise reduction treatment manufacturer

  Precautions for installation of FRP cooling towers4KeCooling tower noise reduction treatment manufacturer

  1. The installation location of the cooling tower should be well ventilated to avoid short circuit of the airflow and the influence of high temperature, high humidity and exhaust of the building or non-clean gas.4KeCooling tower noise reduction treatment manufacturer

  2. The number of cooling towers should be designed according to the number of refrigerators. Multiple composite towers shall be set to ensure that the treatment water quantity of a single composite body matches the cooling water quantity of the refrigerator. The cooling tower is not for equipment use.4KeCooling tower noise reduction treatment manufacturer

  3. When multiple cooling towers are used in parallel, a balance pipe should be set under the water collecting plate, or an electric two-way valve should be set on the inlet and outlet water pipes.4KeCooling tower noise reduction treatment manufacturer

  4. When multiple cooling towers are combined together and the same water collecting plate is used, the air chamber between the parallel towers should be cut off.4KeCooling tower noise reduction treatment manufacturer

  Precautions for piping of FRP cooling tower4KeCooling tower noise reduction treatment manufacturer

  1, circulating water inlet and outlet pipe control pipe, the best downward, avoid the figure of high control pipe, and can not be higher than the bottom of the tank control pipe.4KeCooling tower noise reduction treatment manufacturer

  2, the size of the cooling tower pipe should be installed according to the size of the pipe at the bottom of the tower. Otherwise, too little will affect the effect and too much will waste the material.4KeCooling tower noise reduction treatment manufacturer

  3. The circulating water pump should be installed low in normal operation, below the water level of the lower water tank.4KeCooling tower noise reduction treatment manufacturer

  4. When two or more cooling towers are used together, and only one water pump is used, the water tank shall be equipped with a balance pipe of the cooling tower to make the water level of the two cooling towers be the same.4KeCooling tower noise reduction treatment manufacturer

  Vibration proof hoses (high pressure rubber hoses, etc.) should be used at the inlet and outlet of circulating water above 5 or 4 "(10 cm) to prevent the vibration of the tower body caused by the vibration of the pipeline, and to avoid the damage caused by the rupture of the flume due to improper piping.4KeCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/410.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba