Cooling tower drift water rate is an important measure index, drift water rate is high not only cause poor environment, but also cause a lot of waste, cooling tower drift water is met by many cooling tower manufacturers, and has not been a good solution to the problem. In the chiller system, any form of cooling tower in the working state more or less there is floating water phenomenon. Especially in the open cooling system, the circulating water is in direct contact with the atmosphere, and the bacteria and dust in the air remain in the tower, resulting in the increase of turbidity of the circulating water and the formation of algae in the damp part of the tower, which increases the resistance of the pipeline and the water distribution system, reduces the cooling efficiency and corrodes the tower body. The water droplets drifting into the atmosphere are also likely to carry bacteria and pollution sources, causing pollution to the atmosphere or people.
1. The cooling tower is pumped by the fan to extract the smaller water droplets from the air duct mouth out of the cooling tower.
2. After leaving the cooling tower, the wet and hot air in the saturated state meets the cold air outside and reaches the saturated state, condenses into small drops of water and forms floating water.
3. Water floats out from the inlet of the packing.
1, Large and wide blade wind machine is adopted in the water fan square cross-flow cooling tower. Under the condition of a certain air volume, increasing the windward side can reduce the fan speed, so as to reduce the speed of water droplets and reduce the drift of the air duct.
2. After packing is assembled, the air inlet surface is a honeycombed flow guide, which has a good uniform air distribution effect and improves and stabilizes the heat exchange intensity of water and gas. The inlet end tilts to the tower at an Angle of 30°, through which the airflow can be brought in, while the water droplets cannot be splashed out, thus effectively reducing the floating water loss.
The exterior plate of TRLON air conditioning closed cooling tower is anticorrosive and rust proof, beautiful appearance and long service life. If you are interested in the above products or have questions, please click to contact us for consultation.
Article Address:https://www.trlen.com/baike/392.html
Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.
Contact:Mr. Wang
Free Hotline:4008-8383-95
Company Email:sales@trlon.com
Web Site:https://www.trlen.com/
Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen