To a certain extent, the closed cooling tower is based on the mathematical model of the heat transfer and quality performance of the closed cooling tower, and the analytical model solution is obtained. As a result, when the structural parameters of the cooling tower are constant, the cooling water increases and improves The wet bulb temperature of the inlet air is related to the increased air flow rate and the outlet temperature. The outlet temperature of the cooling water decreases, but the slope of the change gradually decreases.
The water spray and air quality of the closed cooling tower can be used to analyze the mathematical model of the equipment, analyze the influence of its air parameters, and control the height of the closed cooling tower by spraying water on the cooling performance of the cooling tower , Which is helpful for the structural design and performance optimization of liquid refrigerators. In order to study the capacity of the evaporative closed cooling tower, the theoretical model of the closed cooling tower is compared in practice with the closed cooling tower and the open cooling tower is provided. Correspondence between the wet bulb temperature around different cooling towers and the cooling water outlet temperature.
The design details of the diameter and wall thickness of the closed cooling tower, as well as the application of the closed cooling tower, learned the cooling characteristics of the closed cooling tower, and put forward the application research status at home and abroad, and developed the design computer application program And the application prospects of this type of equipment are expected. Using existing mathematical models, using experimental formulas with different coefficients, the thermal efficiency of the cooling tower is predicted and compared.
The closed cooling tower has a large deviation obtained through this formula, and the calculation results obtained by the experimental formula are in good agreement with the test results. The thermal performance of the closed cooling tower can be predicted under different working conditions, and the experiments obtained within the test range must be used. The coefficient of the heat transfer formula and the reasonable prediction of the thermal performance of the cooling tower cooling have a guiding role. The optimized design of the cooling coil of the embodiment is introduced into a complete optimization process and a mathematical model is established, so the limit is determined.
At present, the cooling tower of composite materials can choose the mode according to the user's refrigeration needs and changes in ambient temperature. At the same time, under the condition of saving water, it saves more energy advantages than traditional heat exchangers. The problems studied here include: The closed cooling tower of the mathematical model of the cooling tower compound summarizes the various experiments of the model and formula, as well as the semi-experiment in the model formula involved, and verifies the reliability by simulating related experiments to save energy.
Article Address:https://www.trlen.com/baike/366.html
Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.
Contact:Mr. Wang
Free Hotline:4008-8383-95
Company Email:sales@trlon.com
Web Site:https://www.trlen.com/
Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen