Cooling tower has obvious floating water phenomenon solution

Author:Trlon  Views:  Time:2021-03-16
Cooling tower has obvious floating water phenomenon solution

  Cooling tower water, in fact, you swing the fog, fog for housing construction and urban square or extremely dangerous roads, fog is a specified gas conditions, when the gas is cooled to the point of the fog, the critical state of moisture cooling creates the fog is suspected, with the change of the direction of the wind, to the scope of the various environmental pollution caused by pollution.QedCooling tower noise reduction treatment manufacturer

  When the amount of air absorbed by the fan is reduced, the gas will leave the cooling tower at a slow speed and high temperature. The hot air of the leaving tower (critical state) will meet with the cold air outside, and the fog will eventually increase in large quantities.QedCooling tower noise reduction treatment manufacturer

  Therefore, the key should deal with the air flow of the fan and reduce the temperature of the hot air. The method is as follows:QedCooling tower noise reduction treatment manufacturer

  1, water spraying equipment is the entrance of cooling water and air flow heat exchange, when the water spraying equipment adheres to clay deposition, algae, etc., it must interfere with the flow of gas, so it is necessary to the growth of cooling tower and algae, and carry out cooling water discharge.QedCooling tower noise reduction treatment manufacturer

  2. Clean and dredge the sprinkler nozzle to avoid dirt and obstruction. Clean the cooling water filter and filter screen to ensure adequate water output, increase the effect of heat exhaust, and reduce the exhaust temperature.QedCooling tower noise reduction treatment manufacturer

  3. Clean the fan sheet, calibrate the direction of the fan blade, and try to increase the exhaust air volume.QedCooling tower noise reduction treatment manufacturer

  4, increase the horsepower of the fan, change the fan speed ratio (change the transmission ratio) increase the exhaust air volume.QedCooling tower noise reduction treatment manufacturer

  5. Increase the operating rate and water output of cooling water circulating pump.QedCooling tower noise reduction treatment manufacturer

  6, moderate blocking.QedCooling tower noise reduction treatment manufacturer

  The FRP cooling tower has significant floating water conditionQedCooling tower noise reduction treatment manufacturer

  1. Too much or too little circulating waterQedCooling tower noise reduction treatment manufacturer

  2. Excessive ventilationQedCooling tower noise reduction treatment manufacturer

  3. There is bias current in the packing of cooling towerQedCooling tower noise reduction treatment manufacturer

  4. Speed ratio of water distribution equipment is too fastQedCooling tower noise reduction treatment manufacturer

  5. Improper installation position of water sleeve (water retaining plate)QedCooling tower noise reduction treatment manufacturer

  Cooling tower has significant floating water condition solutionQedCooling tower noise reduction treatment manufacturer

  1. Adjust the valve to the cooling tower suitable for water consumption or change the capacity to matchQedCooling tower noise reduction treatment manufacturer

  2. Reduce the fan speed ratio or change the direction of the fan blade or change the fan suitable for exhaust air volumeQedCooling tower noise reduction treatment manufacturer

  3. Find out the cause and make it evenQedCooling tower noise reduction treatment manufacturer

  4. Adjust to a suitable speed ratioQedCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/348.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba