Trlon air conditioner manufacturers have silent cooling towers, closed cooling towers and cooling tower noise reduction, maintenance and transformation services.
National Service Hotline National Service Hotline:

4008-8383-95

Your current location:HOME > News > FAQ

FAQ

Analysis of Causes of Short Circuit in Closed Cooling Tower

Author:Trlon  Views:  Time:2020-12-09
Analysis of Causes of Short Circuit in Closed Cooling Tower

  In addition to its own quality problems, the short-circuit failure of a closed cooling tower can also be caused by the following reasons. Next, the editor of trlon will tell you the common faults and solutions that cause short circuits in closed cooling towers.B6yCooling tower noise reduction treatment manufacturer

  1. The cooling tower mechanical equipment is running under load, so that the motor and water pump will run at the working voltage or over the working voltage for a long time. In particular, it should be noted that the starting current of the cooling tower motor water pump is 3-5 times the working voltage, so it is reasonable to try to avoid starting the mechanical equipment with load or overload operation (the working voltage of the important load motor water pump and normal conditions (Matching volume of lower running current)B6yCooling tower noise reduction treatment manufacturer

  2. Closed cooling tower motor and water pump work daily in a humid office environment. The cooling tower should require the ground insulation layer and the two-color insulation layer of the coil before the motor water pump is started. The requirements for the insulation layer of different working voltages are also different. You can refer to the relevant standards. Pay attention to the moisture-proof and waterproof of the motor water pump during the whole operation of the motor water pump.B6yCooling tower noise reduction treatment manufacturer

  3. The common failures of the cooling tower pump machine cause the motor and water pump to be overloaded, and the current is too much to burn the coil.B6yCooling tower noise reduction treatment manufacturer

  4. The heat dissipation of the closed cooling tower motor water pump is difficult. Usually the motor and water pump coils are air-cooled casings, and the cooling tower submersible sewage pump is a water-cooled heat dissipation casing. Large and medium motor water pumps mostly use air-to-air heat exchangers and air-to-water heat exchangers for cooling. If the cooling circulating water (gas) is disconnected so that the coil cannot dissipate heat, it is likely to damage the coil.B6yCooling tower noise reduction treatment manufacturer

  If you want to know more about the closed cooling tower, remember to contact us for consultation!B6yCooling tower noise reduction treatment manufacturer

Article Address:https://www.trlen.com/baike/259.html

News

Contact

Guangdong Trlon Energy-saving Air Conditioning Equipment Co., Ltd.

Contact:Mr. Wang

Free Hotline:4008-8383-95

Company Email:sales@trlon.com

Web Site:https://www.trlen.com/

Company Address: 1916A, Block A, David Donglong Business Building, Longhua, Longhua District, Shenzhen

Trlon WechatClose
alibaba