Closed cooling towers are a type of large-scale equipment. There are more or less problems in the industry. The editor of trlon below analyzes the prone problems of closed cooling towers and hopes to help you.
1. Fan problem: If the air volume is insufficient, you can properly adjust the angle of the fan blades and adjust the belt. But if the fan blade is broken, there is no other way but to replace it. And one blade is broken, all the blades need to be replaced. Of course, there are many problems with fans, such as the blades and the air ducts, and the vibration of the blades. This requires on-site testing and analysis.
2. The water collector is damaged: cooling towers generally used for many years will have the problem of damage to the water collector. The damage of the water collector will cause the water mist to splash and the water floating rate will soar. It is a waste of water, and it is easy for bacteria to be inhaled into the respiratory tract, causing disease outbreaks. The service life of the closed cooling tower water collector is generally 8-10 years, and it is produced with virgin materials. The above problems are minimal. When the above problems occur, the original water collector is generally repaired as much as possible. It is really damaged and needs to be replaced. Replacement, as the first domestic manufacturer of composite flow cooling towers, the cooling tower water collector adopts an easy-to-replace design, and it only takes 15-20 minutes to complete the replacement.
3. Motor problem: The motor problem is simple, it is nothing more than heat, burnout, vibration, etc. This is related to the quality of the motor, and the vibration may be related to the wear of the bearing. Enclosed cooling tower motors are generally specially customized outdoor motors, which greatly reduce the damage rate of the motor in high temperature, high humidity, and high-intensity environments. Specific problems are analyzed in detail, and most of them can be solved by repair or replacement.
4. Nozzle problems: nozzles are often blocked due to some debris. Use iron wire to clean the debris to dredge. If the nozzles are broken or damaged due to improper operation, they must be replaced.
The above are the failures and solutions of closed cooling towers analyzed by trlon editor. Wuxi Haike Cooling Technology Co., Ltd. adheres to the cooling tower industry standard. It is used to expose the dark side of the industry and brighten the closed cooling tower industry. I offer a meager value, and in order to prevent you from being harmed by unscrupulous companies, the editor will continue to expose the darkness for you. Thank you for your attention, so stay tuned!